功耗电流:+18,-10 mA |
响应时间:≤3 μs |
失调电压:±25 mV |
失调电压温漂:≤±1.5, ≤±1.0 mV/℃ |
带宽:DC±25 kHz |
测量电流范围:±150, ±225, ±300, ±450, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30, ±25 mV |
线性度:≤1% |
绝缘电压:2.5 kV AC |
输出电压温漂:≤±1.5, ≤±1.0 mV/℃ |
额定输入电流:±50, ±75, ±100, ±150, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:+18, -10 mA |
响应时间:≤3 μS |
失调电压:±25 |
失调电压温漂:≤±1.5, ≤±1.0 |
带宽:DC±25 KHz |
测量电流范围 (Ip):±150, ±225, ±300, ±450, ±600, ±900 A |
电源电压:±15 ±5% |
磁失调电压:±30 |
线性度:≤1% |
绝缘电压:2.5 kV AC (50Hz, 1min) |
输出电压温漂:≤±1.5, ≤±1.0 |
额定输入电流 (Ipn):±50, ±75, ±100, ±150, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:T |
功耗电流:≤±15 mA |
响应时间:050A/μS, 10%-90% ≤3 μS |
失调电压:±25 mV |
失调电压温漂:≤±1.0, ≤±0.75 mV/℃ |
带宽:DC±25 KHz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30, ±25 mV |
线性度:≤1 %FS |
绝缘电压:2.5 KV |
输出电压温漂:≤±1.0, ≤±0.75 mV/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:≤±15 mA |
响应时间:50A/μs, 10%-90% |
失调电压:±25 mV |
失调电压温漂:≤±1.0, ≤±0.75 ppm/℃ |
带宽:DC±25 Hz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30 mV |
线性度:≤1% |
绝缘强度:2.5 kV AC, 50Hz, 1min |
输出电压温漂:≤±1.0, ≤±0.75 ppm/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:≤±15 mA |
响应时间:≤3 μs |
型号:TKC50 BXS, TKC75 BXS, TKC100 BXS, TKC200 BXS, TKC300 BXS, TKC400 BXS, TKC500 BXS, TKC600 BXS |
失调电压:±25 mV |
失调电压温漂:≤±1.0, ≤±0.75 ppm/℃ |
带宽:DC±25 kHz |
测量电流范围(Ip):±150 A, ±225 A, ±300 A, ±600 A, ±900 A, ±900 A, ±900 A, ±900 A |
电源电压:±15±5% |
磁失调电压:±30 mV |
线性度:≤1% |
绝缘电压:2.5 kV AC, 50 Hz, 1 min |
输出电压温漂:≤±1.0, ≤±0.75 ppm/℃ |
额定输入电流(Ipn):±50 A, ±75 A, ±100 A, ±200 A, ±300 A, ±400 A, ±500 A, ±600 A |
额定输出电压:±4±1% |
功耗电流:≤15 mA |
响应时间:≤3 μs (50A/μs, 10%-90%) |
型号:TKC50 BXR, TKC75 BXR, TKC100 BXR, TKC200 BXR, TKC300 BXR, TKC400 BXR, TKC500 BXR, TKC600 BXR |
失调电压:±25 mV |
失调电压温漂:≤±1.0 mV/℃, ≤±0.75 mV/℃ |
带宽:DC±25 kHz (-3dB) |
测量电流范围(Ip):±150 A, ±225 A, ±300 A, ±600 A, ±900 A |
电源电压:±15 V (±5%) |
磁失调电压:±30 mV |
线性度:0-±Ipn |
绝缘电压:2.5 kV AC (50Hz, 1分钟) |
输出电压温漂:≤±1.0 mV/℃, ≤±0.75 mV/℃, ≤1 mV/℃ |
额定输入电流(Ipn):±50 A, ±75 A, ±100 A, ±200 A, ±300 A, ±400 A, ±500 A, ±600 A |
额定输出电压:±4 V (±1%) |
功耗电流:+25, -15 mA |
响应时间:≤5 μs |
失调电压:±25, ±30, ±25 mV |
失调电压温漂:≤±1.0 ppm/℃ |
带宽:DC±25 Hz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% |
线性度:≤1% |
绝缘电压:2.5 kV AC, 50Hz, 1min |
输出电压温漂:≤±0.75, ≤±1.0, ≤±0.75 ppm/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% |
功耗电流:+15, -10 mA |
响应时间:050A/μS, 10%-90% ≤3 μS |
失调电压:±25 mV |
失调电压温漂:≤±1.5 ppm/℃ |
带宽:DC: ±25 Hz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30±25 mV |
线性度:≤1 %FS |
绝缘电压:2.5 kV AC, 50Hz, 1min |
输出电压温漂:≤±1.5 ppm/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:≤25 mA |
响应时间:μS KHz |
失调电压:±25 mV |
失调电压温漂:≤±1.5 ppm/℃ |
带宽:@-3dB DC±25 |
测量电流范围:±150, ±225, ±300, ±450, ±600, ±900 A |
电源电压:±15±5% |
磁失调电压:±30 mV |
线性度:≤1 %FS ≤3 |
绝缘电压:2.5 kV |
输出电压温漂:≤±1.5 ppm/℃ |
额定输入电流:±50, ±75, ±100, ±150, ±200, ±300, ±400, ±600 A |
额定输出电压:±4±1% |
功耗电流:+18, -10 mA |
响应时间:≤1 μS |
失调电压:±25 mV |
失调电压温漂:±30 mV/℃ |
带宽:DC±25 KHz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900, ±900, ±900, ±900 A |
电源电压:±15 ±5% |
磁失调电压:±25 mV |
线性度:≤±1.0 %FS |
绝缘电压:2.5 KV |
输出电压温漂:≤±1.0 mV/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% |
功耗电流:+18, −10 mA |
响应时间:050A/μS, 10%-90% ≤3 μS |
失调电压:±25 mV |
失调电压温漂:≤±1.5, ≤±1.0 ppm/℃ |
带宽:DC±25 Hz |
测量电流范围(Ip):±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30, ±25 mV |
线性度:≤1 %FS |
绝缘电压:2.5 kV AC, 50Hz, 1min |
输出电压温漂:≤±1.5, ≤±1.0 ppm/℃ |
额定输入电流(Ipn):±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:+18, −10 mA |
响应时间:≤3 μs |
失调电压:±25 V |
失调电压温漂:≤±1.5, ≤±1.0 V/℃ |
带宽:DC±25 KHz |
测量电流范围:±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30, ±25 V |
线性度:≤1 %FS |
绝缘电压:2.5 KV |
输出电压温漂:≤±1.5, ≤±1.0 mV/℃ |
额定输入电流:±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:+18, −10 mA |
响应时间:≤3 μs |
失调电压:±25 mV |
失调电压温漂:≤±1.5, ≤±1.0 ppm/℃ |
带宽:DC±25 kHz |
测量电流范围:±150, ±225, ±300, ±600, ±900 A |
电源电压:±15±5% V |
磁失调电压:±30, ±25 mV |
绝缘电压:2.5 kV AC, 50Hz, 1min |
输出电压线性度:≤±1.5, ≤±1.0, ≤1% |
额定输入电流:±50, ±75, ±100, ±200, ±300, ±400, ±500, ±600 A |
额定输出电压:±4±1% V |
功耗电流:≤25 mA |
响应时间/带宽:@−3dB DC±25 Hz |
失调电压:±25 mV |
失调电压温漂:≤±1.5 μV/℃, ≤±1.0 μV/℃ |
测量电流范围:±150A, ±225A, ±300A, ±450A, ±600A, ±900A, ±900A, ±900A |
电源电压:±15±5% V |
磁失调电压:±30 mV, ±25 mV |
线性度:≤1 %FS, ≤3 μS |
绝缘电压:2.5 kV AC, 50Hz, 1min |
输出电压温漂:≤±1.5 μV/℃, ≤±1.0 μV/℃ |
额定输入电流:±50A, ±75A, ±100A, ±150A, ±200A, ±300A, ±400A, ±600A |
额定输出电压:±4±1% |
功耗电流:≤25 mA |
响应时间/带宽:@−3dB DC±25 Hz |
失调电压:±25 mV |
失调电压温漂:≤±1.5 μV/℃, ≤±1.0 μV/℃ |
测量电流范围:±100A, ±150A, ±200A, ±300A, ±400A, ±600A, ±800A, ±900A |
电源电压:±15±5% V |
磁失调电压:±30 mV, ±25 mV |
线性度:≤1 %FS, ≤3 μS |
绝缘电压:2.5 kV (50Hz, AC, 1min) |
输出电压温漂:≤±1.8 μV/℃, ≤±1.2 μV/℃ |
额定输入电流:±50A, ±75A, ±100A, ±150A, ±200A, ±300A, ±400A, ±600A |
额定输出电压:±5±1% |
功耗电流:≤15 mA |
响应时间:≤6 μS(@IP=IPN) |
失调电压:≤±2 mV |
失调电压漂移:≤±2 mV(@−40~+85℃) |
带宽:DC±25 KHz(@−3dB) |
测量电流范围:±600, ±600, ±600, ±700, ±700, ±700, ±900 A |
电源电压:+15 ±5% |
磁失调电压:≤±0.1 mV |
线性度:≤1 %FS(@IP=IPN) |
绝缘电压:2.5 KV(@50HZ/60Hz, AC, 1min) |
额定输入电流:±40, ±60, ±90, ±100, ±110, ±130, ±200 A |
额定输出电压:±40 ±1%FS mV |
功耗电流:+18 mA, −10 mA |
响应时间:50 A/μs, 10%-90% |
失调电压温漂:≤±1.0 mV/℃ |
带宽:DC±25 kHz |
测量电流范围(Ip):±300 A, ±600 A, ±900 A, ±1000 A, ±1000 A, ±1000 A |
电源电压:±15 V ±5% |
磁失调电压:≤±30 mV |
线性度:±Ipn范围内 |
绝缘电压:50 Hz, AC, 1 min |
输出电压温漂:≤±1.0 mV/℃ |
零点失调电压:≤25 mV |
额定输入电流(Ipn):±100 A, ±200 A, ±300 A, ±400 A, ±500 A, ±600 A |
额定输出电压:±4 V ±1% |
功耗电流:+18 mA, −10 mA |
响应时间:50 A/μs, 10%-90% |
失调电压温漂:≤±1.0 mV/℃ |
测量电流范围:±300 A, ±600 A, ±900 A, ±1000 A, ±1000 A, ±1000 A |
电源电压:±15 V ±5% |
磁失调电压:≤±30 mV |
绝缘电压:50 Hz, AC, 1 min |
零点失调电压:≤25 mV |
额定输入电流:±100 A, ±200 A, ±300 A, ±400 A, ±500 A, ±600 A |
额定输出电压:±4 V ±1% |
功耗电流:+18, −10 mA |
响应时间:≤5 μS |
失调电压温漂:≤±0.5(Typ), ≤±0.75(Max) mV/℃ |
带宽:DC±25 KHz |
测量电流范围(Ip):±300 A, ±900 A, ±1500 A, ±2400 A, ±3000 A, ±3000 A, ±3000 A |
爬电距离:>8.5 mm |
电气间隙:>8.5 mm |
电源电压:±15±5% V |
相对漏电起痕指数:>275 V |
磁失调电压:≤±30 mV |
线性度:≤1 %FS |
绝缘电压:5.0 KV |
输出电压温漂:≤±0.5(Typ), ≤±0.75(Max) mV/℃ |
零点失调电压:≤15 mV |
额定输入电流(Ipn):±100 A, ±300 A, ±500 A, ±800 A, ±1000 A, ±1500 A, ±2000 A |
额定输出电压:±4±1% V |
功耗电流:+18, −10 mA |
响应时间:≤1 %FS |
失调电压温漂:≤±0.5(Typ), ≤±0.75(Max) mV/℃ |
带宽:DC±25 KHz |
测量电流范围(Ip):±300 A, ±900 A, ±1500 A, ±2400 A, ±3000 A, ±3000 A, ±3000 A |
爬电距离:>8.5 mm |
电气间隙:>8.5 mm |
电源电压:±15±5% V |
相对漏电起痕指数:>275 V |
磁失调电压:≤±30 mV |
线性度:≤±0.5(Typ), ≤±0.75(Max) mV/℃ |
绝缘电压:5.0 KV |
零点失调电压:≤15 mV |
额定输入电流(Ipn):±100 A, ±300 A, ±500 A, ±800 A, ±1000 A, ±1500 A, ±2000 A |
额定输出电压:±4±1% V |
功耗电流:+18 mA |
响应时间:≤5 μs |
失调电压温漂:≤±20 ppm/℃, ≤±0.5(Typ), ≤±0.75(Max) |
带宽:DC±25 Hz |
测量电流范围(Ip):±200 A, ±600 A, ±1000 A, ±1200 A, ±1600 A, ±2000 A, ±3000 A |
电源电压:+5±5% V |
线性度:≤1% |
绝缘电压:5.0 kV AC, 50Hz, 1min |
输出电压温漂:≤±0.5(Typ), ≤±0.75(Max) |
零点失调电压:≤±15 mV |
零点电压:2.5±0.5% |
额定输入电流(Ipn):±100 A, ±300 A, ±500 A, ±600 A, ±800 A, ±1000 A, ±2000 A |
额定输出电压:±1±1% |
功耗电流:+18, -10 mA |
响应时间:≤5 μs |
失调电压温漂:≤±0.5 (Typ), ≤±0.75 (Max) mV/°C |
带宽:DC±25 Hz |
测量电流范围:±300 A, ±600 A, ±1000 A, ±1600 A, ±2000 A, ±2400 A, ±3000 A, ±3000 A |
电源电压:±15±5% V |
磁失调电压:≤±30 mV |
线性度:≤1% |
绝缘电压:5.0 kV AC (50Hz, 1min) |
输出电压温漂:≤±0.5 (Typ), ≤±0.75 (Max) mV/°C |
零点失调电压:≤15 mV |
额定输入电流:±100 A, ±300 A, ±500 A, ±800 A, ±1000 A, ±1200 A, ±1500 A, ±2000 A |
额定输出电压:±4±1% V |
功耗电流:+28, -15 mA |
响应时间:≤1 μs |
失调电压:≤±20 mV |
失调电压温漂:≤±1.0 mV/℃ |
带宽:DC±25 Hz |
测量电流范围(Ip):±600A, ±1200A, ±1500A, ±1800A, ±2250A, ±2400A, ±3000A, ±3000A, ±3000A |
电源电压:±15±5% V |
磁失调电压:±15 mV |
线性度:≤±1.0%FS |
绝缘电压:3 kV AC, 1 min |
绝缘阻抗:≥1000 MΩ @ DC 500V |
输出电压温漂:≤±1.0 mV/℃ |
额定输入电流(Ipm):±200A, ±400A, ±500A, ±600A, ±750A, ±800A, ±1000A, ±1200A, ±1500A |
额定输出电压:±4±1% V |
功耗电流:+28,-15 mA |
响应时间:≤5 μS |
失调电压:±20 mV |
带宽:DC±25 KHz |
幅度电压温漂:≤±0.5 mV/°C |
测量电流范围:±1500A, ±1800A, ±2400A, ±3000A, ±4500A, ±5000A, ±6000A, ±10000A |
电源电压:±15±5% V |
磁失调电压温漂:±10 mV/°C |
精度:≤±1 %FS |
线性度:≤±0.5 %FS |
绝缘电压:5 KV |
绝缘阻抗:1000 MΩ |
输出漂移:≤±0.5 mVc %FS |
额定输入电流:±500A, ±600A, ±800A, ±1000A, ±1500A, ±2500A, ±3000A, ±5000A |
额定输出电压:±4±1% V |
功耗电流:+12±5% V |
响应时间:≤5 μS |
失调电流温漂:≤±0.05 mA/℃ |
带宽:DC±25 KHz |
幅度电压温漂:≤±0.0075 mA/℃ |
测量电流范围(Ip):±500 A, ±600 A, ±800 A, ±1000 A, ±1500 A, ±2000 A, ±2500 A |
电源电压:12±8±1.0% |
磁失调电流:12±0.1 mA |
精度:≤±1.0 %FS |
线性度:≤±1.0 %FS |
绝缘电压:5 KV |
绝缘阻抗:1000 MΩ |
零点电流:+35+Io |
额定输入电流(Ipn):±500 A, ±600 A, ±800 A, ±1000 A, ±1500 A, ±2000 A, ±2500 A |
额定输出电流(Io):±750 A, ±900 A, ±1200 A, ±1500 A, ±2250 A, ±3000 A, ±3750 A |
查看更多